

{"id":34661,"date":"2025-08-25T15:54:36","date_gmt":"2025-08-25T06:54:36","guid":{"rendered":"https:\/\/ksensors.co.kr\/product\/calt-cas60-4-20ma-%ec%b6%9c%eb%a0%a5-%ec%8b%b1%ea%b8%80%ed%84%b4-%ec%95%b1%ec%86%94%eb%a3%a8%ed%8a%b8-%ec%97%94%ec%bd%94%eb%8d%94-2\/"},"modified":"2025-08-25T15:54:36","modified_gmt":"2025-08-25T06:54:36","slug":"calt-cas60-4-20ma-%ec%b6%9c%eb%a0%a5-%ec%8b%b1%ea%b8%80%ed%84%b4-%ec%95%b1%ec%86%94%eb%a3%a8%ed%8a%b8-%ec%97%94%ec%bd%94%eb%8d%94-2","status":"publish","type":"product","link":"https:\/\/casscale.kz\/en\/product\/calt-cas60-4-20ma-%ec%b6%9c%eb%a0%a5-%ec%8b%b1%ea%b8%80%ed%84%b4-%ec%95%b1%ec%86%94%eb%a3%a8%ed%8a%b8-%ec%97%94%ec%bd%94%eb%8d%94-2\/","title":{"rendered":"CALT \/ CAS60 \/ 4-20mA \ucd9c\ub825 \uc2f1\uae00\ud134 \uc571\uc194\ub8e8\ud2b8 \uc5d4\ucf54\ub354"},"content":{"rendered":"<div class=\"elementor-element elementor-element-5be4bc57 elementor-widget elementor-widget-heading\" data-id=\"5be4bc57\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n<div class=\"elementor-widget-container\">\n<h2 class=\"elementor-heading-title elementor-size-default\">Specification<\/h2>\n<\/div>\n<\/div>\n<div class=\"elementor-element elementor-element-2b6e2dd0 elementor-widget elementor-widget-text-editor\" data-id=\"2b6e2dd0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n<div class=\"elementor-widget-container\">\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"156\">Operating Voltage<\/td>\n<td width=\"494\">10-30Vdc\u00a0 polarity protection<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Current Consumption<\/td>\n<td width=\"494\">&lt; 110mA\u00a0 \u00a0(24V power supply)\u00a0 no load<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Output Signal<\/td>\n<td width=\"494\">RS485 and 0-5V dual independent output, you can set the length, angle, speed application output<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Linearity Resolution<\/td>\n<td width=\"494\">1\/4096FS<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Repeatability Precision<\/p>\n<p>Signal adjustment<\/td>\n<td width=\"494\">Repeatability \u00b12BIT( Actual precision related with installation and shaft concentricity.)\u00a0\u00a0 Resolution or direction settable, external setting line preset functiion.<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Operating Temperature<\/td>\n<td width=\"494\">-40\u201475\u2103\u00a0\u00a0\u00a0\u00a0 Programming temperature range\uff1a0\u2103\uff5e\uff0b70\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Storage Temperature<\/p>\n<p>Protection class<\/p>\n<p>Vibration &amp; shock<\/td>\n<td width=\"494\">-40\u201480\u2103<\/p>\n<p>IP67 for housing\u00a0\u00a0 \u00a0\u00a0\u00a0IP65 for shaft<\/p>\n<p>20g\uff0c10\uff5e2000Hz\uff1b100g\uff0c6ms<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Permissible Rotation Rate<\/td>\n<td width=\"494\">2400rpm<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Connection Cable<\/td>\n<td width=\"494\">1m 8-core shielded cable.<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Overall Feature<\/td>\n<td width=\"494\">Clamping flange or synchronous flange, metal enclosure, sealed dual-bearing structure ( see attached drawing of overall dimension)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"156\">Signal Conditioning<\/td>\n<td width=\"494\">Can 0V output trim, 5V output trim; direction can be set; preset position, external reset, such as external zero<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"elementor-element elementor-element-745834d elementor-widget elementor-widget-heading\" data-id=\"745834d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n<div class=\"elementor-widget-container\">\n<h2 class=\"elementor-heading-title elementor-size-default\">Example (output signal evolution)<\/h2>\n<\/div>\n<\/div>\n<div class=\"elementor-element elementor-element-263354f4 elementor-widget elementor-widget-text-editor\" data-id=\"263354f4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n<div class=\"elementor-widget-container\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-34646\" src=\"https:\/\/casscale.kz\/wp-content\/uploads\/2025\/08\/CAS-signal-9.png\" alt=\"\" width=\"446\" height=\"215\" \/><\/p>\n<\/div>\n<\/div>\n<div class=\"elementor-element elementor-element-1e9d22c7 elementor-widget elementor-widget-heading\" data-id=\"1e9d22c7\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n<div class=\"elementor-widget-container\">\n<h2 class=\"elementor-heading-title elementor-size-default\">Installation dimensions (mm)<\/h2>\n<\/div>\n<\/div>\n<div class=\"elementor-element elementor-element-a03ad22 elementor-widget elementor-widget-text-editor\" data-id=\"a03ad22\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n<div class=\"elementor-widget-container\">\n<p>Clamping &amp; synchro flange(default)<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-34649\" src=\"https:\/\/casscale.kz\/wp-content\/uploads\/2025\/08\/cas60-dimension-1-4.png\" alt=\"\" width=\"689\" height=\"392\" \/><\/p>\n<p>synchro flange<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-34652\" src=\"https:\/\/casscale.kz\/wp-content\/uploads\/2025\/08\/cas60-dimension-2-4.png\" alt=\"\" width=\"894\" height=\"506\" \/><\/p>\n<p>Blind hollow shaft<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-34655\" src=\"https:\/\/casscale.kz\/wp-content\/uploads\/2025\/08\/cas60-dimension-3-4.png\" alt=\"\" width=\"1014\" height=\"532\" \/><\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li>Universal 0-5V &amp; RS485 output, single-turn absolute encoder<\/li>\n<li>Multiple resolutions are available, such as 12-bit<\/li>\n<li>60mm outer diameter, Clamping flange, servo flange or blind hollow shaft, the international standard structure<\/li>\n<li>A \u201cmagnetic detection mode\u201d, with excellent impact and vibration resistance<\/li>\n<li>Programmable, intelligent absolute value encoder; professional setting software, convenient for user operation<\/li>\n<li>Wide operating voltage, low current consumption<\/li>\n<li>External reset wire to set the default location, easy installation, no need to find ZERO.<\/li>\n<li>Housing IP67, shaft IP65<\/li>\n<\/ul>\n","protected":false},"featured_media":34635,"template":"","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0},"product_brand":[1038],"product_cat":[1060],"product_tag":[1040,1086,1099,1100,1041],"class_list":["post-34661","product","type-product","status-publish","has-post-thumbnail","product_brand-calt-en","product_cat-analog-encoder-en","product_tag-rotary-encoder-en","product_tag---en","product_tag--en","first","instock","taxable","shipping-taxable","product-type-simple"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/casscale.kz\/en\/wp-json\/wp\/v2\/product\/34661","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/casscale.kz\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/casscale.kz\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/casscale.kz\/en\/wp-json\/wp\/v2\/product\/34661\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/casscale.kz\/en\/wp-json\/wp\/v2\/media\/34635"}],"wp:attachment":[{"href":"https:\/\/casscale.kz\/en\/wp-json\/wp\/v2\/media?parent=34661"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/casscale.kz\/en\/wp-json\/wp\/v2\/product_brand?post=34661"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/casscale.kz\/en\/wp-json\/wp\/v2\/product_cat?post=34661"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/casscale.kz\/en\/wp-json\/wp\/v2\/product_tag?post=34661"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}